[ Avaa Bypassed ]




Upload:

Command:

www-data@3.147.2.112: ~ $
# For documentation see sane-mustek_pp(5)

# Global options:
# ===============
#
# option no_epp
#
#	    Disable parallel port mode EPP: works around a known bug in
#	    the Linux parport code. Enable this option, if the backend
#	    hangs when trying to access the parallel port in EPP mode:
#
#	          # SANE_DEBUG_SANEI_PA4S2=128 scanimage -L
#	          ...
#  hangs here  -> [sanei_pa4s2] sanei_pa4s2_readbyte: read in EPP mode
#
# Scanner definition template:
# ============================
#
#  scanner <name> <port> <type>
#     option <optname> <optval>?
#     option <optname> <optval>?
#     ...
#
#  where:
#
#     <name> is an arbitrary name for the scanner (eg. Mustek-1200CP)
#
#     <port> is the parallel port to which the scanner is connected
#            Possible values are 0x378, 0x278, and 0x3bc. For Linux, the
#            mapping between ports an numbers is different for kernel
#            version 2.2 and 2.4. Port 0x378 corresponds to lp0 on 2.4 kernel.
#            If you are using libieee1284, you can as well use parport0, etc..
#	     If you use the magic value * the port is probed.
#
#     <type> is an identification of the scanner type.
#            Possible values are:
#              - cis600    (for Mustek 600CP & OEM versions),
#              - cis1200   (for Mustek 1200CP & OEM versions),
#              - cis1200+  (for Mustek 1200CP+ & OEM versions),
#              - ccd300    (for Mustek 600 III EPP & OEM versions)
#	       - ... more types will be added in the future
#
#     <optname> is a name of an option, and <optval> an optional value
#               for the option.
#               Currently available options for *CIS* type scanners are:
#                 - top_adjust <value>:
#                      Vertical adjustment of origin, in millimeter.
#                      Values between -5.0 and +5.0 mm are possible
#                      (floating point).
#                      Default: 0.0
#                 - slow_skip:
#                      Boolean option. Disables fast skipping to the start
#                      of the scan region. May be necessary in case fast
#                      skipping results in inaccuracies.
#                      Default: fast skipping enabled
#                 - bw <value>:
#                      Black/white discrimination value for lineart scans.
#                      Pixel values below that value are considered black,
#                      others are considered white. Range: 0-255.
#                      Default: 127
#
#		Currently available options for *CCD* type scanners are:
#		  - wait_bank <value>
#		       usecs to wait for a bank change. Positive integer
#		       values are possible. You shouldn't mess with this
#		       parameter.
#		       Default: 700
#		  - bw <value>
#                      Black/white discrimination value for lineart scans.
#                      Pixel values below that value are considered black,
#                      others are considered white. Range: 0-255.
#                      Default: 127
#		  - top <value>
#		       Scanlines to skip to the top area. Positive integer
#		       values are possible. 47 and 56 are values I know of.
#		       Default: 47
#
#
# Example for a LifeTec LT9350 (Mustek 1200CP clone):
#
#    scanner LT9350 0x378 cis1200
#       option top_adjust 0
#       option bw 127
#
# Example for Mustek 6000P
#
#    scanner 6000P 0x378 ccd300
#        option top 56
#
#
# Uncomment/customize to your needs
#
# scanner Mustek-600CP 0x378 cis600
# scanner Mustek-1200CP 0x378 cis1200
# scanner Mustek-1200CP+ 0x378 cis1200+
# scanner Mustek-600-IIIEP 0x378 ccd300
#
# auto probing:
#
# scanner mustek-cis600 * cis600
# scanner mustek-cis1200 * cis1200
# scanner mustek-cis1200+ * cis1200+
# scanner mustek-ccd300 * ccd300

Filemanager

Name Type Size Permission Actions
dll.d Folder 0755
abaton.conf File 25 B 0644
agfafocus.conf File 13 B 0644
apple.conf File 24 B 0644
artec.conf File 25 B 0644
artec_eplus48u.conf File 4.04 KB 0644
avision.conf File 547 B 0644
bh.conf File 29 B 0644
canon.conf File 26 B 0644
canon630u.conf File 193 B 0644
canon_dr.conf File 3.87 KB 0644
canon_pp.conf File 1.13 KB 0644
cardscan.conf File 552 B 0644
coolscan.conf File 34 B 0644
coolscan2.conf File 754 B 0644
coolscan3.conf File 754 B 0644
dc210.conf File 983 B 0644
dc240.conf File 983 B 0644
dc25.conf File 703 B 0644
dell1600n_net.conf File 490 B 0644
dll.conf File 1.09 KB 0644
dmc.conf File 12 B 0644
epjitsu.conf File 2.67 KB 0644
epson.conf File 792 B 0644
epson2.conf File 374 B 0644
epsonds.conf File 293 B 0644
escl.conf File 857 B 0644
fujitsu.conf File 3.19 KB 0644
genesys.conf File 2.12 KB 0644
gphoto2.conf File 1.11 KB 0644
gt68xx.conf File 7.77 KB 0644
hp.conf File 497 B 0644
hp3900.conf File 395 B 0644
hp4200.conf File 76 B 0644
hp5400.conf File 238 B 0644
hpsj5s.conf File 23 B 0644
hs2p.conf File 24 B 0644
ibm.conf File 38 B 0644
kodak.conf File 367 B 0644
kodakaio.conf File 2.54 KB 0644
kvs1025.conf File 39 B 0644
leo.conf File 112 B 0644
lexmark.conf File 119 B 0644
ma1509.conf File 187 B 0644
magicolor.conf File 1.22 KB 0644
matsushita.conf File 665 B 0644
microtek.conf File 268 B 0644
microtek2.conf File 279 B 0644
mustek.conf File 2.07 KB 0644
mustek_pp.conf File 3.71 KB 0644
mustek_usb.conf File 808 B 0644
nec.conf File 13 B 0644
net.conf File 573 B 0644
p5.conf File 365 B 0644
pie.conf File 75 B 0644
pieusb.conf File 554 B 0644
pixma.conf File 1.22 KB 0644
plustek.conf File 4.04 KB 0644
plustek_pp.conf File 942 B 0644
qcam.conf File 391 B 0644
ricoh.conf File 29 B 0644
rts8891.conf File 183 B 0644
s9036.conf File 13 B 0644
saned.conf File 1.03 KB 0644
sceptre.conf File 48 B 0644
sharp.conf File 1.42 KB 0644
sm3840.conf File 115 B 0644
snapscan.conf File 2.19 KB 0644
sp15c.conf File 10 B 0644
st400.conf File 2.17 KB 0644
stv680.conf File 178 B 0644
tamarack.conf File 27 B 0644
teco1.conf File 355 B 0644
teco2.conf File 634 B 0644
teco3.conf File 217 B 0644
test.conf File 1.76 KB 0644
u12.conf File 1.46 KB 0644
umax.conf File 3.01 KB 0644
umax1220u.conf File 386 B 0644
umax_pp.conf File 1.64 KB 0644
xerox_mfp.conf File 3.93 KB 0644